Optris Logo - Affordable temperature measurement solutions
tune

Produktkonfigurator

Das perfekte Optris-Produkt für Ihre Bedürfnisse finden.

IR Thermometer Configurator arrow_forward IR Camera Configurator arrow_forward
Configurator Screen
lens_blur

Optik-Kalkulator

Verwenden Sie den Rechner, um schnell die passende Messfleckgröße für Ihre Anforderungen zu ermitteln.

Explore Now arrow_forward
Calculator Screen
forum

Chat mit Ingenieuren

Online-Service-Support

Öffnungszeiten
Montag – Donnerstag: 08:00 – 17:00
Freitag: 08:00 – 16:00

Chat starten arrow_forward
call

Jetzt anrufen

Sales-Abteilung:
+49 30 500 197-0

Öffnungszeiten
Montag – Donnerstag: 08:00 – 17:00
Freitag: 08:00 – 16:00

 

mail

E-Mail senden

Sales-Abteilung:
[email protected]

Kontakt-Formular arrow_forward
construction

Reparatur anfordern

Serviceanfrage für Reparaturaufträge:
[email protected]

Serviceanfrageformular arrow_forward

Optische Auflösung und MFOV

Beugungsgrenzen, Pixelabstand und die physikalischen Grenzen der Infrarotauflösung

Die optische Auflösung ist ein entscheidender Spezifikationsparameter für die Temperaturmessung und beschreibt die Fähigkeit, ein Objekt mit ausreichender Genauigkeit aufzulösen. Ein kleines Sichtfeld eines Messgeräts ist mit einer kleinen Messfleckgröße und einer höheren optischen Auflösung des Messobjekts verbunden.

Aus technischer Sicht hängt die optische Auflösung mit dem optischen System des Messgeräts sowie mit der Detektorgröße bei einem Pyrometer beziehungsweise der Pixelgröße des Sensors bei einer Wärmebildkamera zusammen. Beide Faktoren bestimmen gemeinsam die optische Auflösung für die jeweilige Temperaturmessanwendung. Diese Definition berücksichtigt sphärische und chromatische Aberrationen der Optik, die effektive Fläche des Detektors sowie Streueffekte innerhalb des optischen Systems.

Mehrere miteinander verknüpfte Faktoren im optischen System und im Detektorsystem begrenzen grundsätzlich die optische Auflösung jedes optischen Sensors. Die wichtigsten Einschränkungen sind die durch die Wellenlänge bestimmte Beugung, die Qualität der Optik und die Detektorgröße, die gemeinsam die optische Auflösung eines Infrarotsensors begrenzen.

Die Qualität der Linsen und deren optisches Design bestimmen, wie präzise das System Infrarotstrahlung auf den Detektor fokussieren kann. Optische Aberrationen, Beugungseffekte und eine unvollständige Fokussierung verringern die Fähigkeit des Systems, kleine Details zu unterscheiden, insbesondere bei großen Messabständen.

Der Detektor misst typischerweise die Strahlung eines einzelnen Messflecks. Je kleiner der Detektor ist, desto kleiner kann der auflösbare Messfleck sein – allerdings nur, wenn auch die Optik in der Lage ist, einen entsprechend kleinen Messfleck abzubilden. Letztlich wird dies durch die Beugung begrenzt.

Wenn Infrarotlicht durch eine Linse tritt, entsteht aufgrund der Beugung kein perfekter Punkt, sondern ein beugungsbegrenztes Airy-Scheibchen. Die Punktspreizfunktion beschreibt diese unscharfe Intensitätsverteilung in der Bildebene. Abbildung 1 veranschaulicht, wie eine Punktquelle durch Beugung verbreitert wird und sich ihre Energie dadurch auf benachbarte Pixel verteilt.

Figure. 1. When light passes through any aperture or lens of any size, diffraction occurs, and an Airy disk intensity illuminates the bolometer pixel. The Airy disk is the smallest point to which a beam of light can be focused. The diameter of this pattern is related to the wavelength and the size of the aperture. To measure the total infrared radiation energy, the entire pattern must be sampled by all covered pixels.
Figure. 1. When light passes through any aperture or lens of any size, diffraction occurs, and an Airy disk intensity illuminates the bolometer pixel. The Airy disk is the smallest point to which a beam of light can be focused. The diameter of this pattern is related to the wavelength and the size of the aperture. To measure the total infrared radiation energy, the entire pattern must be sampled by all covered pixels.

Nach dem Rayleigh-Kriterium sind zwei Punktquellen gerade noch auflösbar, wenn das Maximum eines Airy-Scheibchens mit dem ersten Minimum des anderen zusammenfällt. Die kleinste auflösbare Strukturgröße [math]∆_lmin[/math] wird durch die folgende Gleichung definiert, wobei λ die Infrarotwellenlänge, f die Brennweite der Linse und D deren Durchmesser ist. Dieser Wert definiert zugleich den Radius des Airy-Scheibchens:

[math]∆l_min=1.22 (f ∙ λ )/D[/math]

Die optische Auflösung des Systems entspricht dem Kehrwert von ∆lmin. Diese Beugungsgrenze bestimmt die maximal erreichbare Auflösung unabhängig von der Sensorgröße oder dem Pixelabstand. Die optische Auflösung eines optischen Systems wird allgemein als Kehrwert der genannten Gleichung 1/[math]∆l_min[/math] definiert. Der Aperturdurchmesser D spielt eine entscheidende Rolle bei der Bestimmung der Beugungsgrenze – kleinere Aperturen erzeugen größere Airy-Scheibchen und damit eine geringere räumliche Auflösung.

Die folgende Gleichung beschreibt die Form des Airy-Scheibchens:

[math]I\left(x\right)=\ \frac{2\ J_1(\alpha)}{\alpha}[/math]

[math]\alpha=\ \frac{2\pi}{\lambda}\ \bullet\ \frac{ax}{z}[/math]

Dabei ist [math]\ J_1[/math] die Besselfunktion erster Ordnung, a der Aperturradius und z der Abstand zwischen der Apertur und der Bildebene. Dies entspricht dem standardmäßig normierten Profil eines Airy-Scheibchens, wobei die maximale Intensität im Zentrum als 1 definiert wird.

Aufgrund der Beugung ist die kleinste auflösbare Messfleckgröße direkt proportional zur verwendeten Infrarotwellenlänge. Längere Wellenlängen (z. B. 8–14 µm) führen zu größeren beugungsbegrenzten Messflecken als kürzere Wellenlängen (z. B. 1–2 µm). Daher bieten Infrarot-Temperatursensoren, die im kurzwelligen Infrarotbereich arbeiten, grundsätzlich eine bessere optische Auflösung.

Figure. 2. Simulated Airy disk intensity profiles for various infrared camera spectral ranges. The curves represent different wavelength ranges corresponding to specific thermal camera models. The lateral spread of the diffraction pattern increases with longer wavelengths, illustrating the diffraction-limited spatial resolution for each spectral band. Calculations are based on an aperture diameter of 10 mm, an image plane distance of 15 mm, and a focal length of 15 mm.
Figure. 2. Simulated Airy disk intensity profiles for various infrared camera spectral ranges. The curves represent different wavelength ranges corresponding to specific thermal camera models. The lateral spread of the diffraction pattern increases with longer wavelengths, illustrating the diffraction-limited spatial resolution for each spectral band. Calculations are based on an aperture diameter of 10 mm, an image plane distance of 15 mm, and a focal length of 15 mm.

Wenn das Detektorelement deutlich größer als die Wellenlänge ist, bestimmt in erster Linie die Detektorgröße die optische Auflösung. Wenn sich die Abmessungen des Detektors jedoch der Größenordnung der gemessenen Wellenlänge annähern, werden Beugungseffekte relevant und führen zu optischen Begrenzungen. Im Gegensatz zu Pyrometern, die einen einzelnen Detektor zur Messung der Infrarotstrahlung verwenden, nutzen Infrarotkameras zweidimensionale Focal-Plane-Arrays zur Erfassung von Wärmebildern. Die Pixelgröße dieser Arrays liegt häufig in einer ähnlichen Größenordnung wie die Infrarotwellenlänge, wodurch eine grundlegende Beugungsgrenze entsteht, die die erreichbare räumliche Auflösung begrenzt.

Der Begriff Measurement Field of View (MFOV) leitet sich aus diesen theoretischen Überlegungen ab. Während das Instantaneous Field of View (IFOV) das kleinste räumliche Detail beschreibt, das die Kamera bei einem bestimmten Abstand unter der Annahme einer perfekten Optik theoretisch auflösen kann, bezeichnet das Minimum Field of View (MFOV) die erforderliche Größe des Messobjekts, die von einer definierten Anzahl an Pixeln abgedeckt werden muss, um genaue Temperaturmessungen zu ermöglichen.

Die folgenden Abbildungen veranschaulichen, dass bei demselben optischen System eine höhere Pixeldichte die Bildqualität nicht verbessert, da sich die Infrarotenergie über eine Fläche verteilt. Daher muss bei einem kleinen Pixelabstand eine größere Anzahl von Pixeln ausgewertet werden, um eine genaue Temperaturmessung sicherzustellen. Ist das Pixel größer als das Airy-Scheibchen, reicht hingegen die Auswertung eines einzelnen Pixels aus.

0/4
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.
Figure 3: Simulated 3D Airy disk intensity profiles for different detector pixel pitches in infrared thermal imaging systems. The four subfigures correspond to pixel sizes of 8 µm, 12 µm, 17 µm, and 34 µm, respectively. Normalized intensity is plotted versus spatial position in the image plane. While with a large pixel pitch it is sufficient to only consider single detector elements, for a smaller pixel pitch, for correct temperature measurement, multiple pixels have to be considered.

In der Pyrometrie wird das Verhältnis von Abstand zu Messfleckgröße typischerweise als der Schwarzkörperdurchmesser definiert, bei dem das gemessene Strahlungssignal im Vergleich zum Signal eines ausreichend großen schwarzen Strahlers um 10 % abnimmt. Bei Infrarotkameras lässt sich dieses Konzept übertragen, indem die Bildgröße, bei der 90 % der Gesamtenergie eingeschlossen sind, zur Definition des effektiven Messfelds verwendet wird. Dieser Wert steht in direktem Zusammenhang mit der Anzahl der Pixel, die erforderlich sind, um den fokussierten Infrarot-Messfleck vollständig zu erfassen. Fällt die Bildgröße unter diesen Durchmesser für 90 % eingeschlossene Energie, nimmt die pro Pixel erfasste Energie deutlich ab. Dadurch unterschätzen herkömmliche Infrarotkameras, die auf pixelbasierten Intensitätsmessungen beruhen, die tatsächliche Temperatur. Abbildung 4 zeigt die experimentellen Daten; die entsprechenden Größen für 90 % eingeschlossene Energie sind in Tabelle 1 aufgeführt. Bei diesen Messungen, die bei einer Schwarzkörpertemperatur von 100 °C durchgeführt wurden, führt eine Verringerung der erfassten Energie um etwa 10 % zu einer Temperaturabweichung von ungefähr 7,2 °C. Die Abweichung ist bei Kameras mit kleineren Pixelabständen am stärksten ausgeprägt. Kleinere Objektstrukturen können zwar weiterhin erkannt werden, die kleinste zuverlässige Strukturgröße für eine genaue Temperaturmessung wird jedoch in erster Linie durch die optische Beugungsgrenze des Infrarotsystems und nicht allein durch die Pixelgröße bestimmt.

Pixelabstand [µm] Bildgröße bei 90 % eingeschlossener Energie [µm] Für eine genaue Intensitätsmessung erforderliche Pixel
34 47.85 2
17 44.24 3
12 42.08 4

 

Tabelle 1. Bildgröße bei 90 % eingeschlossener Energie im Vergleich zu unterschiedlichen Pixelabständen. Diese experimentellen Daten zeigen, dass bei Infrarotkameras mit kleinen Pixelabständen des Focal-Plane-Arrays für genaue Intensitäts- oder Temperaturmessungen eine größere Anzahl von Pixeln berücksichtigt werden muss.

 

Figure 4: Encircled energy concerning the focused image size on the focal plane array. With a decreasing aperture, a single pixel no longer receives the total energy. A centered individual pixel receives less energy as the image size becomes smaller, and the point spread function spreads across multiple pixels of the focal plane array due to the diffraction limit, which is displayed as a black line.
Figure 4: Encircled energy concerning the focused image size on the focal plane array. With a decreasing aperture, a single pixel no longer receives the total energy. A centered individual pixel receives less energy as the image size becomes smaller, and the point spread function spreads across multiple pixels of the focal plane array due to the diffraction limit, which is displayed as a black line.

Zusammenfassend stellen aus physikalischer Sicht die beugungsbegrenzten Eigenschaften des optischen Systems eine natürliche Grenze für die optische Auflösung und die Bildqualität dar – selbst bei einer höheren Pixelanzahl und kleineren Pixelgrößen. Da die Abmessungen der einzelnen Pixel bereits in einer ähnlichen Größenordnung wie die erfasste Wellenlänge liegen, ist die Auflösung des optischen Systems begrenzt.

Im langwelligen Infrarotbereich ist bei einem Pixelabstand von 17 µm im Allgemeinen erforderlich, dass sich das Messobjekt über mindestens drei Pixel erstreckt, entsprechend dem Dreifachen des IFOV, um sicherzustellen, dass 90 % der emittierten Strahlung erfasst werden und das Distanzverhältnis zuverlässig definiert ist. Ist der Pixelabstand kleiner als 12 µm, müssen für einen korrekten Temperaturmesswert mehr Pixel berücksichtigt werden. Bei optischen Systemen geringerer Qualität können unter bestimmten Umständen sogar bis zu 10×10 Pixel erforderlich sein, um 90 % der Energie zu erfassen. Eine Hochleistungs-Kameraoptik ermöglicht darüber hinaus einen größeren Messabstand bei gleicher Anzahl an Pixeln auf dem Detektor oder die präzise Temperaturmessung kleinerer Strukturen und Objekte.

Abbe-Grenze für Mikroskope

Bei mikroskopischen oder stark vergrößernden Infrarotaufnahmen wird die Auflösung häufig anhand der Abbe-Grenze beschrieben. Dieser Ansatz führt den Begriff der numerischen Apertur ein, die den Winkelbereich beschreibt, innerhalb dessen Licht in das optische System eintreten oder aus diesem austreten kann. Insbesondere bei mikroskopischen Anwendungen wird häufig auf die Abbesche Auflösungsgrenze Bezug genommen. Die Abbe-Definition liegt sehr nahe an der zuvor dargestellten Gleichung, berücksichtigt jedoch die numerische Apertur anstelle der Blendenzahl und liefert dadurch die kleinste Größe d eines noch auflösbaren Objekts. Die numerische Apertur (NA) des Systems beschreibt die Winkel, innerhalb derer Licht in das System eintreten oder aus diesem austreten kann. Beide Größen stehen miteinander in Zusammenhang. Im Gegensatz zur Blendenzahl berücksichtigt die numerische Apertur zusätzlich den Brechungsindex n des Mediums, in dem das System arbeitet.

[math]d=\ \frac{\lambda\ }{2n\ \sin{(\varphi)}}=\ \frac{\lambda\ }{2NA}[/math]

Summary

  • Die optische Auflösung bestimmt, wie klein ein Objekt sein kann, damit eine Wärmebildkamera oder ein Pyrometer dessen Temperatur noch genau messen kann.
  • Eine höhere Auflösung kann durch größere Linsen oder kürzere Wellenlängen erreicht werden, jedoch setzt die Beugung stets eine Grenze.
  • Die durch die Wellenlänge bestimmte Beugung, die Qualität der Optik und die Detektorgröße begrenzen gemeinsam die optische Auflösung eines Infrarotsensors.
  • Um bei Wärmebildkameras genaue Temperaturmesswerte zu gewährleisten, muss das Objekt mehrere Pixel abdecken – typischerweise mindestens 3× IFOV oder bei Optiken geringerer Qualität entsprechend mehr. Dadurch wird das Measurement Field of View (MFOV) definiert.

Sources

  1. Rogalski A, Martyniuk P, Kopytko M. Challenges of small-pixel infrared detectors: a review. Rep Prog Phys. 2016 Apr;79(4):046501. doi: 10.1088/0034-4885/79/4/046501. Epub 2016 Mar 23. PMID: 27007242. https://doi.org/10.1088/0034-4885/79/4/046501
  2. Dieter Lohrmann, Roy T. Littleton, Colin E. Reese, Dan Murphy, and Jay N. Vizgaitis „Uncooled long-wave infrared small pixel focal plane array and system challenges,“ Optical Engineering 52(6), 061305 (31 January 2013). https://doi.org/10.1117/1.OE.52.6.061305
  3. Christel-Loic Tisse, Jean-Luc Tissot, and Arnaud Crastes „An information-theoretic perspective on the challenges and advances in the race toward 12μm pixel pitch megapixel uncooled infrared imaging“, Proc. SPIE 8353, Infrared Technology and Applications XXXVIII, 83531M (31 May 2012); https://doi.org/10.1117/12.918534
  4. Norbert Schuster, John Franks: Challenges, constraints and results of lens design in 8-12 micron waveband for bolometer-FPAs having a pixel pitch of 12micron, Proc. SPIE, Vol. 8704-132 (2013) https://doi.org/10.1117/12.2021637
  5. Marc Guillaumont et al: Recent thermoresistive material evolutions at LYNRED for improving uncooled microbolometer products thermal sensitivity, Proc. SPIE 12107, Infrared Technology and Applications XLVIII, 1210716 (27 May 2022); https://doi.org/10.1117/12.2618494
  6. Sébastien Cortial et al: Status of 8.5μm pitch bolometer developments at Lynred, Proc. SPIE 12534, Infrared Technology and Applications XLIX, 125341A (13 June 2023); https://doi.org/10.1117/12.2663455

COMPARE: