Optris brand for affordable infrared cameras and pyrometers
tune

Product Configurator

Finding the perfect Optris product for your needs.

IR Thermometer Configurator arrow_forward IR Camera Configurator arrow_forward
Configurator Screen
lens_blur

Optics Calculator

Use the Calculator to quickly determine the right spot size for your needs.

Explore Now arrow_forward
Calculator Screen
forum

Chat with Engineers

Online service support

Opening Hours
Monday – Thursday: 08:00 – 17:00
Friday: 08:00 – 16:00

Chat Now arrow_forward
call

Call Us

Sales department:
+49 30 500 197-0

Opening Hours
Monday – Thursday: 08:00 – 17:00
Friday: 08:00 – 16:00

 

mail

Email Us

Sales department:
[email protected]

Contact Us arrow_forward
construction

Request a Repair

Service request for repair orders:
[email protected]

Service Request Form arrow_forward

CT-Ethernet TCP/IP and Modbus TCP Interface-Kit

Industrial Fieldbus Communication Kit for Optris CT Pyrometers

CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit
CT-Ethernet TCP/IP and Modbus TCP Interface-Kit

The CT-Ethernet TCP/IP and Modbus TCP Interface Kit allows industrial communication for CT, CTlaser, or CTratio infrared devices. The interface board goes inside the CT electronic box and uses a 4-pin M12 connector with IP67 protection. It communicates through the TCP/IP or Modbus TCP protocols. Network settings, stored on the board, let it integrate into industrial networks. Users can manage the interface using provided software tools, a web browser, or example code, including pre-installed C# scripts. The device supports both static and DHCP IP modes, which improves its versatility and ease of use in various industrial applications. It also offers several communication options, such as an Excel sheet with macros for TCP/IP communication and a description of the Modbus TCP protocol.

  • Ethernet TCP/IP interface
  • Modbus TCP interface
  • Transfer speed up to 100Mbit/s
  • 4-pin M12 connector
  • Full documentation and coding example

150,00

Product Description

The CT-Ethernet TCP/IP and Modbus TCP Interface Kit facilitate industrial communication for CT devices. Installed inside the CT electronic box, it uses a 4-pin M12 connector with IP67 protection and supports TCP/IP and Modbus TCP protocols. Network settings enable integration into industrial networks. Users can manage the interface through software tools, a web browser, pre-installed C# scripts, an Excel sheet, and a description of the Modbus TCP protocol.

Specification

General Specifications

  • Environmental rating: IP67 (Nema-4) (when installed)
  • Operating temperature: -20 °C to 80 °C
  • Relative humidity: 10 – 95 %, non-condensing

Interface Board Characteristics

  • Port Protocol: Ethernet TCP/IP or Modbus TCP, selectable
  • Transfer speed: up to 100 Mbit/s
  • Connector: 1 x M12, D-coded

Pin Assignment

  • RX-N: Blue
  • RX-P: White
  • TX-N: Orange
  • TX-P: Yellow
Downloads
FAQs

How can I change the IP address and the IP mode?

Please review the manual.

Do I need additional cables?

Ethernet cables shall be ordered separately.

What is the difference between Profinet and standard Ethernet?

Profinet integrates the physical Ethernet cabling with a special protocol for networking, combining them within its additional application layer protocol to enable industrial communication.

How do I reset the interface?

The interface must be switched off. Press the SW button on the board and switch the box on in the meantime. The LED flashes red. Release the button the fifth time it flashes. The LED flashes green 5 times as confirmation.

Can I connect multiple devices to the same network?

Yes, but each of the devices must get an own IP address but they must be in the same subnet.

Which connector is used?

The industrial interface has a 4-pin, M12, D-coded connector.

Where are the network settings stored?

The network settings are stored on the interface board, which communicates with the Optris devices via the serial interface. The network settings remain on the board when the Optris devices are exchanged.

Scope of Supply
  • 1x interface board (static IP mode, IP address: 192.168.0.102)
  • 1x M12 4-pin connector
  • 1x extension cable (20cm) with RJ45 socket and M12 4-pin connector