Optris Logo - Affordable temperature measurement solutions
tune

Product Configurator

Finding the perfect Optris product for your needs.

IR Thermometer Configurator arrow_forward IR Camera Configurator arrow_forward
Configurator Screen
lens_blur

Optics Calculator

Use the Calculator to quickly determine the right spot size for your needs.

Explore Now arrow_forward
Calculator Screen
forum

Chat with Engineers

Online service support

Opening Hours
Monday – Friday:
8:00 am – 5:00 pm

 

Chat Now arrow_forward
call

Call Us

Sales department:
+1 603 766-6060

Opening Hours
Monday – Friday:
8:00 am – 5:00 pm

 

mail

Email Us

Sales department:
[email protected]

Contact Us arrow_forward
construction

Request a Repair

Service request for repair orders:
[email protected]

Service Request Form arrow_forward

CTlaser F2

High-Performance Two-piece Industrial Infrared F2 Pyrometer for Gas Temperature Measurement with Laser-Sighting

CTlaser F2
CTlaser F2
CTlaser F2
CTlaser F2
CTlaser F2
CTlaser F2

Engineered in Germany for the toughest industrial environments, the Optris CTlaser F2 series changes the game in non-contact temperature measurement of CO2 flames and process gases. This specialized infrared thermometer is made for accuracy in critical areas like combustion optimization, waste incineration, and monitoring chemical reactors, where precise gas temperature data is crucial for efficiency, safety, and emission control.

The key innovation of the CTlaser F2 is its unique spectral response. By using a specific measuring wavelength that targets CO₂ absorption bands, it provides unmatched accuracy in measuring flame and hot gas temperatures. It effectively filters out interference from nearby surfaces or particles. It operates across a wide temperature range from 200 °C to 1650 °C (392 °F to 3002 °F). Its sturdy, heat-resistant stainless steel measuring head can handle ambient temperatures up to 85 °C (-4 °F to 185 °F) without needing external cooling.

Built for easy Industry 4.0 integration, the CTlaser F2 offers excellent connectivity. It supports a wide range of industrial interfaces, including EtherNet/IP, Profinet, Modbus RTU, and Modbus TCP, along with standard analog outputs. This versatility makes it easy to integrate into both new and existing plant control networks. Configuring the device, visualizing data, and logging information is straightforward with the free compactConnect software, which works on any mobile phone or PC.

To ensure perfect fit for your setup, a range of interchangeable lenses is available to improve the distance-to-spot ratio. Various mounting accessories provide a secure and reliable installation. Each CTlaser F2 unit reflects the precision of German engineering, undergoing final calibration and a thorough check at our German facility before shipping. For accurate gas temperature measurement, rely on the Optris CTlaser F2.

CTlaser F2 — Important Features:

  • Temperature range: 200 °C to 1650 °C (392 °F to 3002 °F)
  • Distance-to-spot size ratio: 45:1
  • Response time: 10 ms
  • Spectral range: 4.24 µm
  • Operating temperature: -20 °C to 85 °C (-4 °F to 185 °F)
  • For Temperature Measurement of hot CO₂ gas

From $1,690.00

excl. sales taxes, custom tariffs and shipping

News
Product Description

The CTlaser F2 offers precision non-contact temperature measurement of carbon dioxide flame gases, reaching temperatures up to 1650 °C. This precision is crucial for combustion processes, garbage burning, and operations within chemical reactors, instilling confidence in the pyrometers performance.

Gas molecules emit infrared energy at specific wavelengths, forming absorption bands in the infrared spectrum. Infrared thermometers are equipped with filters that select wavelengths based on the absorption bands of targeted gases, determining the spectral range. The CTlaser F2’s spectral range of 4.24 μm enables accurate carbon dioxide temperature readings, with temperature ranges varying from: 200 °C to 1450 °C for the F2 model and 400 °C to 1650 °C for the F2H model.

The CTlaser F2 features a system accuracy of ±1% and repeatability of ±0.5% or +0.5 °C at an ambient temperature of 23 ±5 °C. With a spot size starting from 1.6 mm and Distance to Spot ratio of 45:1 with different focus points, the infrared sensor ensures accuracy and flexibility in various settings.

The pyrometers‘ double laser aiming marks offer precise aiming support and minimize alignment errors. This innovative system employs two laser beams to trace the infrared optical path and accurately indicate the spot’s position and size, regardless of distance.

The pyrometer features a two-piece design with a separate electronics box, providing a diverse array of analog and digital outputs for seamless integration into various industrial processes and control systems. It remains operational in ambient temperatures up to 85 °C without requiring cooling, with the laser automatically shutting off at 50 °C to conserve power.

Enhanced with Optris accessories such as air purging, cooling jackets, and mounting flanges, the CTlaser F2 is designed for integration into diverse gas monitoring applications, with customization options like different cable sizes provided for specific customer requirements.

Manufactured in Germany, these pyrometers undergo meticulous calibration to meet government standards such as PTB or NIST, ensuring the highest level of accuracy in temperature measurement. Optris provides comprehensive support for the CTlaser F2 series, including consultation on industrial applications and after-sales support, ensuring optimal performance and user satisfaction.

Specification
MODEL CTlaser F2 CTlaser F2H
DETECTOR
Detector Thermopile
Measurement Principle Single color
Spectral Range 4.24 μm
Response Time 10 ms
Exposure Time 10 ms
Sampling Frequency 100 Hz
Exchangable Sensing Head No
OPTICAL
Distance to Spot ratio (D:S) 45:1
Spot size (SF optics) 26.7 mm at 1200 mm
Other optics (FF/CF optics / add. CF lens) CF1: 1.6 at 70 mm
CF2: 3.4 at 150 mm
CF3: 4.5 at 200 mm
CF4: 10 at 450 mm
Focus fixed
SIGHTING
Laser Sighting Double point laser with 635 nm at max 1mW
Video Sighting none
MEASUREMENT
Object Measurement Range 200 … 1450 °C 400 … 1650 °C
Accuracy ±1 %
Repeatability ±0.5 % of reading +0.5 °C **2)
Temperature Coefficient ± 0.05 K/K or ± 0.05 % / K **3)
Thermal Sensitivity (NETD) 100 mK
Warm-up time 10 min
Emissivity /Transmissivity/ Reflectivity 0.100 – 1.100
Slope N/A
INTERFACES
Interface USB / RS232 / RS485 / Profibus DP / Ethernet / Relay
Supported Protocols USB 2.0, Optional: EtherNet/IP / Ethernet TCP / Modbus TCP / Modbus RTU / Profinet / Profibus
Compatible Software Compact Connect, IRmobile
ANALOG INPUT/OUTPUT
Direct output/input 0-20 mA/4-20 mA/0-5 V/0-10 V/t/c (K/J)
Output impedances max. 500 Ω (with 8-36 V DC) for mA output
min. 100 kΩ load impedance for mV output
thermocouple 20 Ω
Cable length 3 m (standard), 8 m, 15 m
SIGNAL PROCESSING
Configuration Compact Connect or IRmobile
Operation Autonomous Standalone
Capabilities Average, Peak hold, Valley hold, Advanced peak hold with threshold and
hysteresis, Triggered signal output, Triggered peak hold function (adjustable via software)
GENERAL
Size Sensing head: Ø50 x 100 mm, M48x1.5
Electronics: 122 mm x 70 mm x 27 mm
Housing Material Stainless Steel
Weight 600 g (sensing head) / 420 g (electronics)
Country of Origin Germany
ENVIRONMENTAL & CERTIFICATIONS
Operating Temperature Range Sensing head: –20 °C … 85 °C **4)
Electronics: –20 … 85 °C
Storage Temperature Range –40 … 85 °C
Relative humidity 10 – 95 %, non condensing
Protection Class IP 65, NEMA 4
EMC 2014/30/EU
Shock IEC 60068-2-27 (25 G and 50 G)
Vibration IEC 60068-2-6 (sinus shaped)
IEC 60068-2-64 (broadband noise)
Standards CE, UKCA, RoHS
POWER
Power Supply 8 – 36 V DC / 5 V USB / max. 1.2 W
Power Consumption <250mW with laser
Current Draw max 160 mA
Part number OPTCTLF2 OPTCTLF2H
Additional Remarks 1) 90% energy
2) at ambient temperature 23 ± 5°C, object temperature > 0°C ;
3) for ambient temperatures <18°C and >28°C; whichever is greater
4) 50 °C with laser ON
Areas of Application
Software

The Optris CompactConnect software improves the functionalities of Optris fixed infrared pyrometers, offering various monitoring, analysis, and control features beyond basic temperature measurement. It includes features like visualizing temperature trends with temperature-time diagrams and documentation. The software enables data logging, automatic process controls, parameterization of the pyrometer via configuration settings, and setting up programmable outputs and inputs. Additionally, it provides advanced signal-processing functionalities. Compact Connect The Optris IR mobile allows users to set up and commission an Optris infrared pyrometer or infrared camera with an Android smartphone or tablet. This tool becomes handy for commissioning and aligning the infrared cameras field of view or adjusting the configuration. The app analyzes the connected infrared cameras live infrared image stream with auto hot and cold spot detection. For pyrometers, a temperature-time diagram or the video signal is displayed. This app works on most Android devices running 5.0+ with a USB port supporting USB-OTG (On The Go). Google Play

Downloads
FAQs

What distance-to-spot size ratio is correct for the application?

The measuring object’s size and the infrared thermometers optical resolution determine the maximum distance between the sensing head and the measuring object. To prevent measuring errors, the object should completely fill out the field of view of the optics. Consequently, the spot should always be at least the same size as the object or should be smaller than that.

Can I change the sensor cable?

The sensing head cable can also be exchanged if necessary. To avoid influences on the accuracy use an exchange cable with the same wire profiles and specification like the original one

Can I pare the sensor head with another electronics box?

Yes, after exchanging a head the calibration code of the new head must be entered into the electronics. The calibration code is fixed on a label on the head. Do not remove this label or note the code. The code is needed if the electronic must be exchanged.

How far can I position the CTlaser F2 from the target?

The measuring object’s size and the infrared thermometers optical resolution determine the maximum distance between the sensing head and the measuring object. The object should fill out the optics’ field of view to prevent measuring deviations. Consequently, the spot should always be at least the same size as the object or smaller. The spot size refers to 90% of the radiation energy.

How can I improve the noise amplitude of the sensor?

In the CT models, the head cable must not be moved during the measurement. Use shielded cables only. The sensor shield has to be grounded. Avoid ground loops and related signal interferences in industrial environments. It might be necessary to interrupt the ground connections inside the electronics box. To do this, switch the jumper inside the electronics box to another position. Review the manual.

How do I aim with a CTlaser F2?

The infrared sensor has an integrated double laser aiming, which helps align the sensor. The measuring spot is located within the two laser points. At the focus point of the appropriate optics, both lasers cross and merge as one dot, marking the minimum spot. The two laser points are for orientation only.

Is the laser dangerous?

The pyrometers laser is a class 2 laser with less than 1mW in the wavelength range of 500 nm to 650nm, according to EN 60825 1:2014. Do not point the laser directly at the eyes of persons or animals! Do not stare into the laser beam. Avoid indirect exposure via reflective surfaces.

The laser switched off?

At ambient temperatures >50 °C the laser will be switched off automatically. The laser should only be used for sighting and positioning of the sensor. A permanent use of the laser can reduce the lifetime of the laser diodes and might heat up the sensor.

Can I trigger the laser externally?

Yes, but the supply line for the sighting laser must be led via a switch or pushbutton, which has to be installed max 2m away from installation site of the sensor for safety purposes. The laser can be activated/ deactivated via this, by the user on site to be installed switch, or via the software.

What is required to install the CTlaser infrared sensor in the CoolingJacket Advanced?

The connector version is needed to install the CTlaser sensor in the CoolingJacket Advanced.

Can you connect two pyrometers to the same computer?

Yes , this is possible. For using the software CompactPlusConnect or CompactConnect (depends on which type of pyrometers you are using) you have to create different instances of the software. You can connect two pyrometers via the USB ports. It is also possible to connect the two pyrometers with a RS485 interface. You can connect the first pyrometer via the provided RS485-USB adapter to the PC.

I am interested in integrating the CTlaser Infrared Thermometer into a science/industrial prototype, which will be controlled via code written in Python. Does the OTC SDK include libraries for thermometers or just cameras?

The OTC SDK does include only libraries for cameras.

Scope of Supply
  • CTlaser F2 with 3m cable
  • 1x mounting nut
  • 1x mounting bracket
  • CTlaser Manual
Accessories

COMPARE:

Compare