Optris Logo - Affordable temperature measurement solutions
tune

Product Configurator

Finding the perfect Optris product for your needs.

IR Thermometer Configurator arrow_forward IR Camera Configurator arrow_forward
Configurator Screen
lens_blur

Optics Calculator

Use the Calculator to quickly determine the right spot size for your needs.

Explore Now arrow_forward
Calculator Screen
forum

Chat with Engineers

Online service support

Opening Hours
Monday – Friday:
8:00 am – 5:00 pm

 

Chat Now arrow_forward
call

Call Us

Sales department:
+1 603 766-6060

Opening Hours
Monday – Friday:
8:00 am – 5:00 pm

 

mail

Email Us

Sales department:
[email protected]

Contact Us arrow_forward
construction

Request a Repair

Service request for repair orders:
[email protected]

Service Request Form arrow_forward

PI 640i Microscope Optics with 2X Magnification

Precision High-Resolution VGA Infrared Microscope Camera with 2X Magnification.

PI 640i Microscope Optics with 2X Magnification PI 640i Microscope Optics with 2X Magnification PI 640i Microscope Optics with 2X Magnification PI 640i Microscope Optics with 2X Magnification PI 640i Microscope Optics with 2X Magnification Heizstrahler MO2X PI 640i Microscope Optics with 2X Magnification PI 640i Microscope Optics with 2X Magnification PI 640i Microscope Optics with 2X Magnification

The PI640i infrared microscope package, featuring 2X magnification, provides precise temperature data for small electronic devices and MEMS, crucial in semiconductor applications. Users can visualize thermal variations and measure minute targets, relying on detector resolution. Its optics focus infrared heat onto the IR camera’s detector elements. The highest-performing objective can detect 8 µm temperature changes within a 5.4 mm x 4.0 mm (.21 in x .16 in) field of view. Integration of a high-resolution IR camera with German-designed objectives and precise adjustment facilitates accurate measurements. A pixel pitch of 17 µm allows a small MFOV of 4 x 4 pixels, ensuring precise measurements. The camera supports frame rates of 32 Hz or 125 Hz for microscopic thermal imaging.

  • Analysis of small chip-level components down to 8 μm
  • Spectral range: 8 µm to 14 µm
  • High pixel resolution of 640 x 480
  • Frame rate: 32 Hz, up to 125 Hz of sub-images
  • With a temperature resolution (NETD) of 80 mK
  • Exchangeable, focusable optics for the most flexible use of the camera
  • Microscope stand included for hands-free simultaneous operation/testing

$17,450.00

excl. sales taxes, custom tariffs and shipping

News
Product Description

The PI 640i infrared microscope kit with 2X magnification provides a solution for engineers needing precise temperature data on small electronic devices or Micro-Electro-Mechanical Systems (MEMS). This kit allows users to see thermal changes and measure tiny targets, which depends on the resolution of the detector. The system’s optics direct infrared heat from the device to the IR camera’s detector elements, ensuring accurate and detailed thermal analysis of small components.

Engineers often find differences between temperature readings from contact thermocouples and those from a well-equipped infrared camera, especially when working with small targets. This difference usually occurs because of the thermal bridge effect from the thermocouple connection. This effect can conduct heat and distort measurement accuracy. In these situations, non-contact infrared cameras typically produce more reliable results, as they sidestep the heat conduction issues tied to contact methods.

Just like microscopes that work within the visible spectrum, picking the right optic involves a balance between the total visible field and the smallest target that needs observation and measurement. The best PI 640i microscope objective can pick up temperature changes on targets as tiny as 8 µm across a field of view of 5.4 mm x 4.0 mm. By combining a high-resolution IR camera with German-designed infrared microscope objectives and a precision mounting stage, users can adjust the working distance precisely, ensuring accurate and detailed thermal analysis of small components.

IR camera manufacturers often promote a single pixel size or IFOV (Instantaneous Field of View) to highlight a camera’s ability to resolve small targets. However, it’s crucial to understand that accurate temperature measurement with an iinfrared camera requires multiple pixels. Cameras with smaller detector pitches might need around 7 x 7 pixels to give temperature readings within the camera’s specified accuracy. The MFOV (Measurement Field of View) specification is essential for correct temperature measurements.

In addition to low thermal noise, the ideal pixel pitch size of 17 µm for long-wavelength infrared radiation allows for a small Measurement Field of View (MFOV) of only 4 x 4 pixels. Using high-quality and larger optics improves image quality, reduces distortion, and maintains even attenuation across the image. Users have access to various interchangeable lens optics to frame properly and maximize pixel count on the target that needs measuring. The infrared camera operates at a frame rate of 32 Hz in standard mode and 125 Hz in high-speed subframe mode, making it suitable for monitoring fast manufacturing processes.

The PI 640i works with Optris PIX Connect software, available for free with no-cost updates. This software includes features for detecting hot and cold spots, creating histograms, temperature profiling, image subtraction, and other thermal image processing tools. For researchers and process engineers, the PC-based PIX Connect platform offers strong thermal image processing capabilities, allowing users to extract and document fully calibrated temperature measurements from any pixel in the scene.

Users can extract time-versus-temperature data from live thermal video feeds and recorded thermal video files that contain stored temperature data. Engineers can use the data collection features to find the highest, lowest, and average temperatures from any area, regardless of shape or size, and receive complex alarm signals. The system also allows engineers to replay stored thermal video frame by frame, capturing and storing radiometric images and taking snapshots during temperature changes. This capability ensures thorough monitoring and detailed analysis of thermal events over time.

Many engineers collect data from various locations on electronic devices over long periods using the Temperature/Time feature, which logs data at user-defined intervals and saves it in .csv files. Some engineers prefer taking full images and using calibrated sequence files or calibrated .tiff images captured at specified intervals. The Snapshot sequence storage routine also allows users to store a complete temperature matrix in CSV files at their chosen intervals, providing a detailed record of temperature data for in-depth analysis and reporting.

Specification
MODEL PI 640i LT 10°x 8° MO2X
DETECTOR
Optical resolution Full resolution: 640×480 pixels
Linescan: 640×120 pixels
Pixel pitch 17 µm
Detector Uncooled bolometer
Spectral Range 8 – 14 µm
Optical Filter Optional: CO2 10.6 µm
Frame rate Full resolution: 32 Hz
Linescan: 125 Hz
OPTICAL
Field of View 10°x 8°
Focal length [mm] 60 mm
F Number 1.3
Optical Resolution 440:1
Minimum Distance to Target 15 mm
Interchangeable optics Yes
MEASUREMENT
Object Measurement Range -20…100°C
0…250°C
150…900°C
Accuracy *1) ±2 °C or ±2 %, whichever is greater
Thermal Sensitivity (NETD) *2) 80mK
Smallest detectable Spot Size IFOV: 1 pixel 8 µm
Smallest measurable Spot Size MFOV 32 µm
Measurement Field of View (MFOV) 4×4 pixels
Warm-up time 10 min
Emissivity /Transmissivity/ Reflectivity adjustable: 0.100…1.100
INTERFACES
Interface USB
optional: USB GigE (PoE) interface
Supported Protocols USB 2.0
Compatible Software PIXConnect, ConnectSDK, EasyAPI, ExpertAPI
ANALOG INPUT/OUTPUT
Direct output/input 1x analog output (0/4-20 mA)
1x input (analog or digital); optically isolated
Optional Industrial Process interface (PIF) 2x 0 – 10 V input, digital input (max. 24 V),
3x 0/4 – 20 mA outputs, 3x relay (0 – 30 V/ 400 mA), fail-safe relay
Cable length USB: 1 m (standard), 3m, 5 m, 10 m, 20 m
IMAGE PROCESSING
Configuration via PIXConnect
Operation computer-enabled
Capabilities Measure Areas of Interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions, Temperature-Time Diagrams, Temperature Profiles, Recording & Playing, Triggering
GENERAL
Size 52 x 59 x 139 mm
Housing Material Aluminium housing
Weight 410 g
Tripod 1/4-20 UNC
Focus Manual
Country of Origin Germany
ENVIRONMENTAL & CERTIFICATIONS
Operating Temperature Range 0…50°C
Storage Temperature Range -40…70 °C
Relative humidity 20 – 80 %, non-condensing
Protection Class IP67, NEMA-4
EMC 2014/30/EU
Shock IEC 60068-2-27 (25 G and 50 G)
Vibration IEC 60068-2-6 (sinus shaped)
IEC 60068-2-64 (broadband noise)
Standards CE, UKCA, RoHS
POWER
Power Supply USB
Power Consumption max. 2.5 W
ACCESSORY
Microscope stand Included
ESD pad Included
Dimensions 410 x 230 x 420 mm
Part number OPTPI64ILTMO2XT050
Additional Remarks 1) Accuracy statement effective from 150 °C
Areas of Application
Software

Thermography software optris PIX Connect is included and license-free.All infrared cameras are delivered with the thermography software optris PIX Connect, developed specifically for the extensive documentation and analysis of thermal images. The Windows-based PIX Connect software enables users to tailor the infrared cameras to meet specific requirements. It analyses live and recorded temperature data and triggers alarm signals for process integration.The key to leveraging the Optris infrared camera is a correct configuration. This includes detailed device-specific configurations such as frame rate, measurement range adjustments, external communication settings, and USB/Ethernet configurations. Moreover, PIX Connect facilitates firmware updates and the download of configuration files over the Internet. PIX Connect Optris offers several different SDKs for our Xi and PI thermal imaging cameras. Depending on the operating platform, the infrared camera, the coding language, and the hardware platform, different software interfaces can be utilized: SDK The Optris IRmobile allows users to set up and commission an Optris infrared pyrometer or infrared camera with an Android smartphone or tablet. This tool becomes handy for commissioning and aligning the infrared camera‘s field of view or adjusting the configuration. The app analyzes the connected infrared camera‘s live infrared image stream with auto hot and cold spot detection. For pyrometers, a temperature-time diagram or the video signal is displayed. This app works on most Android devices running 5.0+ with a USB port supporting USB-OTG (On The Go). Google Play

Downloads
FAQs

Can I switch between MO2X and MO44 optics?

Yes. Optics can be changed in the field and deliver calibrated temperature measurements, provided both optics are calibrated with the specific PI 640i they are mated with. For correct calibration, make sure to select the optic attached to the camera from the pull-down optics box in the Device tab of the Configuration menu. All optics that have been calibrated with your serial number camera will be visible in this box if the PC hosting PIX Connect software is online.

Can I use non-microscopic field-of-view optics for larger targets such as printed circuit boards?

Yes. Four additional optics are available for the PI 640i and can be calibrated for use with the camera. This dramatically extends the PI 640i’s application potential, enabling thermal imaging and temperature measurement of full-size printed circuit boards or the products that host them. As with microscope optics, make sure to select the correct calibration file when switching optics.

I have my microscope optics. Can I use these?

Microscope optics developed with visible light cameras will not transmit infrared radiation emitted in the spectral region where the PI 640i is responsive and cannot be used with an infrared camera. Infrared optics not calibrated with the PI 640i could potentially deliver magnified thermal images but will not deliver calibrated temperature measurements.

Why do I need a microscope stage?

Macro focus can be performed using the knurled ring on the outside of the microscope objective but minute adjustments in working distance can dramatically improve image clarity and temperature measurement accuracy. Each microscope package’s stages facilitate this minute working distance adjustment. If the image is not in optimal focus, the temperature measurements will not be accurate.

Can I measure the temperature of the leads connected to my small electronic devices?

Small leads can be seen with powerful infrared microscope optics but are most often made of low-emissivity metals that reflect heat energy. Leads need to be coated with carbon black or flat black paint to be accurately measured with an infrared camera. The same is true for a component (can) made from metal. If a metal lead cannot be treated with a high emissivity coating, the high emissivity connection point of the lead to a device can often serve as an indication that the lead in question is running hotter than desired.

Can I see through the layers on a printed circuit board?

FR-4 and Teflon (PTFE) are common materials used as substrate layers in printing circuit boards. They are not transmissive in the infrared region so you cannot see through them with an IR camera. However, heat from a specific region may conduct up through the various printed circuit board layers to the top board, presenting any conducted heat to an infrared camera targeted at that region on the board surface. The camera settings may need to be optimized to enhance sensitivity so that small shorts from inner layers can be seen. Copper foil inserted in between PCB layers can mute or entirely prevent the flow of heat from the inner layers to the top surface of the board.

Can an infrared camera validate chip and substrate temperatures during PCB manufacturing?

Any infrared measurement requires a clear line of sight between the camera optics and the surface to be measured. Infrared temperature measurements in a reflow oven would be impossible without an access port and mounting and camera cooling provisions. Although there is no system actively marketed now with this capability there is one forced-convection SMT reflow system in development using Optris IR cameras in line scan mode to measure temperatures and create full infrared images through small slits in the oven in four locations.

The stated accuracy in that range for the PI 640i LT is +-2 C, but I was wondering if the accuracy could be further improved with surface emissivity information or calibrated to +-1 C or better

No, the actual temperature accuracy could not be further improved by information on surface emissivity. This is for the PI640i camera ±2 °C or ±2 %.
However, accurate surface information regarding the emissivity is necessary in order to measure the correct temperature based on the reflection ratio on the surface to be measured. An incorrectly set emissivity results in a temperature deviation.

I have a PI 640i and would like to connect it with the USB cable. What do I do if I’m not receiving a signal in the software?

– Check in the WINDOWS device manager that the USB driver was recognized correctly
– Go to Settings/Camera or via search and type in „camera“ and then activate the button “allow apps to access your camera”. Due to an Windows Update this could happen.
–  If you have a black screen on PIXConnect software, this could be because of the bad performance of your graphic chip and hardware acceleration. Regarding this case, reduce the screen resolution of the monitor.
– Check the USB cable and the connector pins on camera and PC side
– Try another USB port of the PC or another PC (if available) to check that the USB cable has no issue
– Maybe the USB power supply of the camera supporting PC is too low
– Using a too long USB cable / a not provided USB cable by Optris or an USB extension cable could be the reason that the software PIXConnect does not get any signal
– Use a PC where you have administrative rights or check with your local administrator

Will optris PIX Connect Software for optris IR Cameras run on my iPad?

No, PIXConnect currently cannot be run on an iOS system (Apple).

Is your infrared camera long-wave (LWIR) or short-wave (SWIR/MWIR)? What’s the typical frame rate? What’s the IFOV (instantaneous field of view / pixel size)? And does it connect to a PC via USB, or what other platforms/interfaces are supported (e.g., Ethernet, etc.)?

Optris provides different types of IR cameras with different wavelengths. Here you can find an overview of the different camera types regarding the spectral ranges, the typical frame rates and the interface versions (USB or Ethernet (ETH)):
Long-wave (LWIR) cameras (spectral range 8-14 µm):
– PI400i LT (80Hz, switchable to 27 Hz),
– PI450i LT (80Hz, switchable to 27 Hz),
– PI640i LT (32 Hz (640×120 px @ 125 Hz),
– Xi80 LT ETH (50 Hz),
– Xi400 LT USB (80Hz, switchable to 27 Hz),
– Xi410 LT ETH (25 Hz (connected via Ethernet,4 Hz connected via USB),
– Xi640 LT USB (32 Hz)
Long-wave (LWIR) cameras (spectral range 7,9 µm):
– PI450iG7 (80Hz, switchable to 27 Hz),
– PI640iG7 (32 Hz (640×120 px @ 125 Hz)
Middle-wave (MWIR) cameras (spectral range 3,9 µm):
– Xi320MT (30 Hz)
Short-wave (SWIR) cameras:
– PI1M (0,85-1,1µm), 32 Hz (382×268 px @ 80 Hz, (switchable to 27 Hz)/ 72×56 px/ 764×8 px @1 kHz)),
– PI08M (780-820 µm), 32 Hz (382×268 px @ 80 Hz, (switchable to 27 Hz)/ 72×56 px/ 764×8 px @1 kHz)) ,
– PI05M (500-540 µm), 764×480 px @ 32 Hz/ 382×288 px @ 80 Hz (switchable to 27 Hz)/ 72×56 px/ 764×8 px @ 1 kHz,
– Xi1M ETH (0,85-1,1µm), 396×300 px, 20 Hz, 396×8 px (auton.: 396×1 px), 500 Hz, 0,85-1,1 μm, Ethernet, USB 2.0 (only 20 Hz), Auton. operation,
– Xi05M ETH (500-540 µm), 396×300 px, 20 Hz, 396×8 px (auton.: 396×1 px), 500 Hz, 500-540 nm, Ethernet, USB 2.0 (only 20 Hz), Auton. operation
The following digital interface kits are for the Xi 80/ 410/ 05M/ 08M cameras available:
– Ethernet TCP/IP / Modbus TCP interface kit
– EtherNet/IP interface kit
– Profinet kit
You can see the IFOV (instantaneous field of view / pixel size) for your IR camera with the different available optics in the optics calculator on the Optris website: Optris IR Camera Calculator (https://optris.com/optris-calculator/camera/)
Example:

What is the bit depth of our camera?

The bit depth of our cameras is 14 bit. The data has 16 bit but only 14 bit are used for the Temperature Data and the other 2 bits are not used.

Can we send the raw ADU data from the camera to another commercial software for processing?

As a rule, we do not disclose any information about raw data. The only option is to use the Connect SDK to output the camera’s ADU values as a matrix. However, these ADU values are uninterpreted. The cameras can send the temperature information and the color information to another commercial software for processing.

Does changing the mode from Temperature to ADU in the Connect SDK change the way that the image is displayed?

No, the way the image is displayed does not change. You can see this in the software examples provided with the PIXConnect software (See the menu HELP => Connect SDK => Examples). Under the configuration menu => External communication => ConnectSDK. You can change the mode from “Temperatures” to “ADU”. This has no influence on the displayed image.

Our company designs and supplies camera systems for steelmaking processes and is exploring different camera types. For this application, would you recommend long-range, near-infrared, or short-wave infrared models?

For steelmaking processes we recommend short-wave infrared cameras as the PI 1M camera, PI 08M camera, PI05M camera , Xi1M camera or Xi 05M camera. Use the lowest wavelength / spectral range as possible!

I’m using the SDK to run SimpleViewer on Linux and have PI Connect installed on Windows. After performing calibration, the thermal image appears entirely black and displays an incorrect temperature reading of 257°F. Which setup or calibration steps could I have overlooked to make this work correctly?

– Regaring the black display in the software PIXConnect , this could be caused by a bad performance of your graphic chip e.g. the hardware acceleration. Reduce the screen resolution of your monitor or if possible reduce the hardware acceleration
– Set the Optimization to “Performance” and remove the hook from “High Speed temperature calculation”

Does the PI 640i support external triggering? Specifically, can I connect a relay output or a controller’s digital output to trigger image acquisition on the camera?

– Yes , the PI 640i camera supports via the software PIXConnect external triggering to record an image.
– You can use an analog input or a digital input signal via the Process Interface (PIF) to trigger the camera.
– In the configuration menu, PIF setting menu , you can set the voltage signal for the analog signal to trigger the camera or you can set the edges conditions for the digital signal to trigger the camera.
– Another possibility to trigger a snapshot via a controller’s digital output is to use the serial communication (if available at the PLC). For this you can use the command list of the serial communication to send the command to take a snapshot.

Which Optris infrared cameras support integration with machine learning frameworks? Do they provide raw thermal image data access via SDK/API (e.g., the OTC SDK), allowing developers to apply custom ML models for tasks like segmentation, classification, or predictive thermal analysis?

The IR cameras do not provide any raw thermal image data access. You get the temperature data via the SDK (OTC SDK) from the camera to your process.

Which Optris infrared camera is best for measuring temperatures during welding processes?

– The choose of the correct Optris infrared camera depends on the temperature range and the type of the welding process.
– For plastic welding , a PI/Xi LT camera can be used (8-14 µm)
– For metal (e.g. steel applications) a short wavelength camera PI 1M/08M/05M , Xi 1M , Xi05M should be used (0.85-1.1 µm , 780-820 µm , 500-540 µm)
– For laser welding applications Optris provides IR cameras with a blocking filter.

Scope of Supply
  • Infrared Camera PI 640i with Microscope optics 2X
  • USB cable (1m)
  • Cable for output/input (1 m) incl. terminal block
  • Rugged outdoor transport case (IP67)
  • Microscope stand
  • Base plate with ESD pad
  • Software package optris PIX Connect
  • Quick Start Guide
Related Products

COMPARE:

Compare