Optris Logo - Affordable temperature measurement solutions
tune

Product Configurator

Finding the perfect Optris product for your needs.

IR Thermometer Configurator arrow_forward IR Camera Configurator arrow_forward
Configurator Screen
lens_blur

Optics Calculator

Use the Calculator to quickly determine the right spot size for your needs.

Explore Now arrow_forward
Calculator Screen
forum

Chat with Engineers

Online service support

Opening Hours
Monday – Friday:
8:00 am – 5:00 pm

 

Chat Now arrow_forward
call

Call Us

Sales department:
+1 603 766-6060

Opening Hours
Monday – Friday:
8:00 am – 5:00 pm

 

mail

Email Us

Sales department:
[email protected]

Contact Us arrow_forward
construction

Request a Repair

Service request for repair orders:
[email protected]

Service Request Form arrow_forward

Xi 410 LT ETH

Fixed Thermal Camera with Ethernet Interface for Standalone Operation

Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH Xi 410 LT ETH

The Optris Xi410 LT ETH thermal camera provides non-contact infrared imaging for industrial monitoring and research. This fixed thermal camera with Ethernet operates in the 8 to 14 µm range, measuring temperatures from -20 °C to 1500 °C (-4 °F to 2732 °F). With a resolution of 384 × 240 pixels and a high distance-to-spot ratio, the camera delivers precise results over long distances. Additionally, the motorized focus enables remote and accurate focus adjustments.

The Xi410 LT ETH is made for industrial environments, with a compact and waterproof housing for stationary setups.

The thermal camera connects via Ethernet at 25 Hz and USB at 4 Hz. It supports smart operation for easy integration into control systems. Features like automatic hotspot detection, direct analog output, and compatibility with major industrial fieldbus systems enhance connectivity. This allows for thermographic analysis directly within the camera. An additional 1.5 Hz mode aids machine integration for streaming temperature data. Autonomous alarms decrease reliance on computers and simplify network setups.

Accessories expand the thermal imager’s functions: water cooling allows operation at temperatures up to 250 °C (482 °F), and air purges help keep the optics clean. Installation options, adapters, and cables provide flexibility for complex systems.

The included PIX Connect software platform has useful features like line scanning, image merging, and the ability to gather thermal data. Developer kits are available for system integrators to create custom software solutions.

Designed and built in Germany, the Xi410 LT ETH thermal camera enables early detection of fires and hotspots in material handling and storage. This helps spot risks before ignition happens. The smart thermal camera monitors thermal trends in plastic processing, electronics manufacturing, and general process engineering to identify deviations. It also offers condition monitoring with temperature alarms and closed-loop control. Furthermore, it supports safety interlocks and zone monitoring on conveyors, cabinets, and enclosures.

Xi 410 LT ETH — Important Features:

  • Temperature range: -20 °C to 1500 °C (-4 °F to 2732 °F)
  • Pixels: 384 x 240 px
  • Frame rate: 25 Hz
  • Interface: Ethernet, USB
  • Operation: Autonomous
  • Small-sized, ruggedized with motorized focus
  • Superb distance to spot size ratio, up to 390:1
  • Autonomous operation
  • Ethernet Interface

From $3,750.00

excl. sales taxes, custom tariffs and shipping

News
Product Description

The Optris Xi 410 LT ETH thermal camera provides non-contact thermal imaging for industrial applications. Operating in the long-wavelength infrared range (8 to 14 µm), it delivers accurate surface temperature measurements and meets various measurement needs. The adjustable field of view and wide temperature range support multiple industrial monitoring scenarios.

Designed for industrial environments, this infrared camera offers mid-resolution imaging at 384 x 240 pixels and measures temperatures from –20°C to 1500°C. The high distance-to-spot-size ratio enables accurate readings at extended distances, surpassing the performance of contemporary pyrometers. The motorized focus allows precise remote adjustment for targeted measurements.

Optris imaging systems use uncooled forward-looking infrared (FLIR) technology for stationary applications. The uncooled two-dimensional detectors generate radiometric thermal images, offering a reliable and cost-effective alternative to line scanners. These thermal cameras autonomously seek thermal hot spots, improving efficiency in industrial monitoring and inspection. All Optris thermal cameras are designed and manufactured in Germany.

The Optris Xi410 LT ETH thermal camera is built to industrial standards for reliable operation in challenging environments. Its compact, waterproof design allows fixed or mounted installations, which benefits process engineering applications.

The Optris Xi410 LT ETH supports connectivity via Ethernet at 25 Hz and USB at 4 Hz. Autonomous operation enables integration into control systems without extensive programming. Key features include automatic spot detection, direct analog output, and compatibility with major industrial fieldbus systems, supporting OEM applications. The 1.5 Hz autonomous mode further streamlines integration into industrial machinery.

The Optris Xi410 LT ETH thermal camera includes advanced software functions such as line scanning and image merging, accessible through the PIX Connect license. PIX Connect offers a comprehensive platform for thermal image processing and data acquisition, supporting research applications. Developer kits are available for system integrators creating custom software solutions.

These features enable the infrared camera to provide accurate, reliable surface temperature measurements for applications such as quality control, condition monitoring, and research. The versatility of the Xi410 LT ETH thermal camera supports integration into various industrial environments and offers a cost-effective solution for fixed-install infrared imaging.

The Xi410 LT ETH thermal camera is compatible with accessories for harsh environments, such as water-cooled housings for operation up to 250°C and air purges to keep the lens clean in dusty conditions. Additional mounting, interface, and cable options are available.

Specification
MODEL Xi 410 LT 18°x12° Xi 410 LT 29°x18° Xi 410 LT 53°x31° Xi 410 LT 80°x44°
DETECTOR
Optical resolution 384:1 238:1 128:1 78:1
Pixel pitch 17 µm 17 µm 17 µm 17 µm
Detector Uncooled bolometer Uncooled bolometer Uncooled bolometer Uncooled bolometer
Spectral Range 8 – 14 µm 8 – 14 µm 8 – 14 µm 8 – 14 µm
Optical Filter No No No No
Frame rate Ethernet: 25 Hz USB: 4 Hz autonomous: 1,5 Hz Ethernet: 25 Hz USB: 4 Hz autonomous: 1,5 Hz Ethernet: 25 Hz USB: 4 Hz autonomous: 1,5 Hz Ethernet: 25 Hz USB: 4 Hz autonomous: 1,5 Hz
OPTICAL
Field of View 18°x12° 29°x18° 53°x31° 80°x44°
Focal length [mm] 20 13 8 6
F Number 1.1 0.9 0.9 0.9
Distance to Spot Ratio (D:S)
Minimum Distance to target 350 mm 350 mm 250 mm 200 mm
Interchangeable optics No No No No
MEASUREMENT
Object Measurement Range -20 – 900 °C (-4 – 1652 °F) | -20 – 1500 °C (-4 – 2732 °F) -20 – 900 °C (-4 – 1652 °F) | -20 – 1500 °C (-4 – 2732 °F) -20 – 900 °C (-4 – 1652 °F) | -20 – 1500 °C (-4 – 2732 °F) -20 – 900 °C (-4 – 1652 °F) | -20 – 1500 °C (-4 – 2732 °F)
Accuracy ±2 °C or ±2 %, whichever is greater ±2 °C or ±2 %, whichever is greater ±2 °C or ±2 %, whichever is greater ±2 °C or ±2 %, whichever is greater
Thermal Sensitivity (NETD)
Smallest detectable Spot Size IFOV: 1 pixel 0.3 mm 0.5 mm 0.7 mm 0.8 mm
Smallest measurable Spot Size MFOV 0.9 mm 1.5 mm 2.1 mm 2.4 mm
MFOV Measurement Field of View 3x3 pixels 3x3 pixels 3x3 pixels 3x3 pixels
Warm-up time 10 min 10 min 10 min 10 min
Emissivity /Transmissivity/ Reflectivity adjustable: 0.100…1.100 adjustable: 0.100…1.100 adjustable: 0.100…1.100 adjustable: 0.100…1.100
INTERFACES
Interface USB 2.0, Ethernet (100 Mbit/s) USB 2.0, Ethernet (100 Mbit/s) USB 2.0, Ethernet (100 Mbit/s) USB 2.0, Ethernet (100 Mbit/s)
Supported Protocols USB, Ethernet (Static), RS485, Serial Communication Optional: Ethernet/IP, ProfiNet, Modbus TCP USB, Ethernet (Static), RS485, Serial Communication Optional: Ethernet/IP, ProfiNet, Modbus TCP USB, Ethernet (Static), RS485, Serial Communication Optional: Ethernet/IP, ProfiNet, Modbus TCP USB, Ethernet (Static), RS485, Serial Communication Optional: Ethernet/IP, ProfiNet, Modbus TCP
Compatible Software PIXConnect, EasyComm, ConnectSDK, EasyAPI, DirectSDK PIXConnect, EasyComm, ConnectSDK, EasyAPI, DirectSDK PIXConnect, EasyComm, ConnectSDK, EasyAPI, DirectSDK PIXConnect, EasyComm, ConnectSDK, EasyAPI, DirectSDK
ANALOG INPUT/OUTPUT
Direct output/input 1x analog output (0/4-20 mA) 1x input (analog or digital); optically isolated 1x analog output (0/4-20 mA) 1x input (analog or digital); optically isolated 1x analog output (0/4-20 mA) 1x input (analog or digital); optically isolated 1x analog output (0/4-20 mA) 1x input (analog or digital); optically isolated
Optional Industrial Process interface (PIF) 3x analog outputs (0/4–20 mA or 0–10 V) or alarm OUT (relais) / 3x inputs (analog or digital) / fail-safe (LED and relay); stackable up to 3 PIFs; optically isolated 3x analog outputs (0/4–20 mA or 0–10 V) or alarm OUT (relais) / 3x inputs (analog or digital) / fail-safe (LED and relay); stackable up to 3 PIFs; optically isolated 3x analog outputs (0/4–20 mA or 0–10 V) or alarm OUT (relais) / 3x inputs (analog or digital) / fail-safe (LED and relay); stackable up to 3 PIFs; optically isolated 3x analog outputs (0/4–20 mA or 0–10 V) or alarm OUT (relais) / 3x inputs (analog or digital) / fail-safe (LED and relay); stackable up to 3 PIFs; optically isolated
Cable length Ethernet / RS485: 20 m (extendable up to 100 m) USB: 1 m (standard), 3 m, 5 m Ethernet / RS485: 20 m (extendable up to 100 m) USB: 1 m (standard), 3 m, 5 m Ethernet / RS485: 20 m (extendable up to 100 m) USB: 1 m (standard), 3 m, 5 m Ethernet / RS485: 20 m (extendable up to 100 m) USB: 1 m (standard), 3 m, 5 m
IMAGE PROCESSING
Configuration via PIXConnect via PIXConnect via PIXConnect via PIXConnect
Operation Autonomous Standalone and/or computer-enabled Autonomous Standalone and/or computer-enabled Autonomous Standalone and/or computer-enabled Autonomous Standalone and/or computer-enabled
Capabilities Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions, Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions, Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions, Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions,
GENERAL
Size Ø 36 mm x 100 mm, thread: M30x1 Ø 36 mm x 100 mm, thread: M30x1 Ø 36 mm x 100 mm, thread: M30x1 Ø 36 mm x 100 mm, thread: M30x1
Housing Material Stainless steel Stainless steel Stainless steel Stainless steel
Weight 216 – 220 g, depending on lens (without mounting bracket) 216 – 220 g, depending on lens (without mounting bracket) 216 – 220 g, depending on lens (without mounting bracket) 216 – 220 g, depending on lens (without mounting bracket)
Tripod 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC
Focus
Country of Origin Germany Germany Germany Germany
ENVIRONMENTAL & CERTIFICATIONS
Operating Temperature Range
Storage Temperature Range -40 ... 70 °C -40 ... 70 °C -40 ... 70 °C -40 ... 70 °C
Relative humidity 10 – 95 %, non condensing 10 – 95 %, non condensing 10 – 95 %, non condensing 10 – 95 %, non condensing
Protection Class IP67, NEMA-4 IP67, NEMA-4 IP67, NEMA-4 IP67, NEMA-4
EMC 2014/30/EU 2014/30/EU 2014/30/EU 2014/30/EU
Shock IEC 60068-2-27 (25 G and 50 G) IEC 60068-2-27 (25 G and 50 G) IEC 60068-2-27 (25 G and 50 G) IEC 60068-2-27 (25 G and 50 G)
Vibration IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise)
Standards CE, UKCA, RoHS CE, UKCA, RoHS CE, UKCA, RoHS CE, UKCA, RoHS
POWER
Power Supply USB or Power over Ethernet or 5-30 VDC USB or Power over Ethernet or 5-30 VDC USB or Power over Ethernet or 5-30 VDC USB or Power over Ethernet or 5-30 VDC
Power Consumption max. 2.5 W max. 2.5 W max. 2.5 W max. 2.5 W
Part number OPTXI41LTF20T090 | OPTXI41LTF20T150 OPTXI41LTF13T090 | OPTXI41LTF13T150 OPTXI41LTF08T090 | OPTXI41LTF08T150 OPTXI41LTF06T090 | OPTXI41LTF06T150
Additional Remarks 1) Accuracy statement effective from 150 °C 2) If this option is ordered, the (20)150 ... 900 °C range is not available 3) Measurement of noise equivalent temperature difference (NETD) according to VDI 5585, method B, 25°C (77 °F) black body temperature (-20…100°C temperature range), frame rate at 20Hz 1) Accuracy statement effective from 150 °C 2) If this option is ordered, the (20)150 ... 900 °C range is not available 3) Measurement of noise equivalent temperature difference (NETD) according to VDI 5585, method B, 25°C (77 °F) black body temperature (-20…100°C temperature range), frame rate at 20Hz 1) Accuracy statement effective from 150 °C 2) If this option is ordered, the (20)150 ... 900 °C range is not available 3) Measurement of noise equivalent temperature difference (NETD) according to VDI 5585, method B, 25°C (77 °F) black body temperature (-20…100°C temperature range), frame rate at 20Hz 1) Accuracy statement effective from 150 °C 2) If this option is ordered, the (20)150 ... 900 °C range is not available 3) Measurement of noise equivalent temperature difference (NETD) according to VDI 5585, method B, 25°C (77 °F) black body temperature (-20…100°C temperature range), frame rate at 20Hz
Software

Thermography software optris PIX Connect is included and license-free.All infrared cameras are delivered with the thermography software optris PIX Connect, developed specifically for the extensive documentation and analysis of thermal images. The Windows-based PIX Connect software enables users to tailor the infrared cameras to meet specific requirements. It analyses live and recorded temperature data and triggers alarm signals for process integration.The key to leveraging the Optris infrared camera is a correct configuration. This includes detailed device-specific configurations such as frame rate, measurement range adjustments, external communication settings, and USB/Ethernet configurations. Moreover, PIX Connect facilitates firmware updates and the download of configuration files over the Internet. PIX Connect Optris offers several different SDKs for our Xi and PI thermal imaging cameras. Depending on the operating platform, the infrared camera, the coding language, and the hardware platform, different software interfaces can be utilized: SDK The Optris IRmobile allows users to set up and commission an Optris infrared pyrometer or infrared camera with an Android smartphone or tablet. This tool becomes handy for commissioning and aligning the infrared camera‘s field of view or adjusting the configuration. The app analyzes the connected infrared camera‘s live infrared image stream with auto hot and cold spot detection. For pyrometers, a temperature-time diagram or the video signal is displayed. This app works on most Android devices running 5.0+ with a USB port supporting USB-OTG (On The Go). Google Play

Downloads
FAQs

Can I trust the temperature measurement of a single pixel?

Due to the diffraction-limited nature of infrared optics, the optical resolution and image quality are physically limited. As the dimensions of the individual pixels are in the same range as the infrared wavelength, users shall ensure that the target is larger than the camera’s MFOV.

What is the speed of the Xi410 LT ETH thermal camera in autonomous operation?

1,5Hz

How do I configure the IP addresses for the Xi410 LT ETH thermal cameras?

Use the PIXConnect software to configure Ethernet settings and the autonomous mode.

Does the Xi410 LT ETH thermal camera support DHCP in the Ethernet mode?

No, the camera must be assigned to a static IP address.

Do I need software to run the infrared camera?

No, the infrared camera can run without the support of a computer. However, for setup and configuration, the software PIXConnect is necessary.

Is the Ethernet cable included?

The PoE adapter to utilize Ethernet is included in the standard scope of supply.

Can I use the Xi410 LT ETH thermal camera with metals or glass?

Other infrared cameras from Optris perform better with that material as they work in a different spectral band.

How do I focus the thermal camera?

The motorized focus can be set with the PIXConnect software. In the PIXConnect software, click on the “distance” button in the toolbar and use the slider.

Where is the Xi410 LT ETH thermal camera made, and does it contain memory components sourced from outside the U.S. or the European Union?

The Xi 410 LT ETH thermal camera is designed, manufactured, and calibrated in Berlin, Germany. Some electronic components may be sourced from outside the EU or the US. Still, it is important to note that the Xi 410 does not store any thermal images or temperature values in non-volatile memory. The Xi 410 LT ETH thermal camera only stores full thermal images, thermal video (.ravi files), and temperature values in the customer PC hosting the PIX Connect software necessary to operate the thermal camera. The camera uses memory components inside the camera electronics, which may be sourced outside the EU or the US to store a reference picture (also called dark picture) of the non-uniformity correction paddle or flag and some reference temperatures used to correct temperature drift. All these memory elements are deleted when the power to the camera head is terminated.

Can the Xi 410 LT ETH thermal camera operate without a connection to a computer?

The Xi 410 can calculate the temperature autonomously without a computer. The temperature data can either be transmitted via the USB or Ethernet interface or output via the process interface. Fieldbus communication is also available.

Can the Xi 410 LT ETH thermal camera send temperature information from spots or areas to my PLC?

The Xi 410 can send temperature information or temperature alarms from the Process Interface connection on the back of the camera. A cable with integrated electronics and a terminal block is included with the camera. It can be programmed in PIX Connect software as an Analog Input (AI) and Digital Input (DI) to control the thermal camera or as an Analog Output (AO) to control the process. The signal level is always 0-10 V (DI = 24 V). An optional industrial process interface is also available, delivering up to three independent temperature values or alarms to a user-supplied PLC. USB-RS485 adapters are available for applications with output requirements for more than three areas.

Is the infrared camera long-wave (LWIR), mid-wave (MWIR), or short-wave (SWIR)?

Optris infrared cameras are available in multiple spectral ranges, with model-specific frame rates and interface options. The Xi 410LT ETH uses LWIR and uses Ethernet.

Which industrial Ethernet/protocol kits are available for Xi410 LT ETH?

The following digital interface kits are available: Ethernet TCP/IP / Modbus TCP interface kit, EtherNet/IP interface kit, PROFINET kit.

What is the IFOV (instantaneous field of view/pixel size) for a given camera and lens?

The IFOV for each camera and optic is provided by the optics calculator in the Optris IR Camera Calculator.

What is the bit depth of the camera data?

The camera temperature data is based on 14-bit information. The data stream is transported in a 16-bit format, with 14 bits used for temperature data and 2 bits unused.

Is raw ADU data provided for processing in third-party software?

Raw data is not disclosed. ADU values can be output as a matrix via the OTC SDK, but they are uninterpreted. Temperature information and color information can be sent to third-party software for further processing.

What does the offset value represent in the analog output setup for Xi410 with PIF module (PIX Connect → Device (PIF) → AO1 → Setup)?

The offset entry is not a manual setting. It is a display field that shows the result of the offset/gain calculation derived from the configured temperature range and the corresponding signal output range.

After connecting an Xi410 to PIX Connect via Ethernet, why can a “frame timeout” occur even though the IP address is correct and ping responds?

In Windows, camera access permissions can prevent image acquisition even when network connectivity is correct. In the Windows settings search, “camera” should be opened, and the option “allow apps to access your camera” should be enabled.

What are the associated part numbers for this product?

OPTXI40LTF20T090, OPTXI41LTF20T090, OPTXI41LTF13T090, OPTXI41LTF08T090, OPTXI41LTF06T090, OPTXI41LTF20T150, OPTXI41LTF13T150, OPTXI41LTF08T150, OPTXI41LTF06T150, DDPXI41LTF20T090, DDPXI41LTF13T090, DDPXI41LTF08T090, DDPXI41LTF06T090, DDPXI41LTF20T150, DDPXI41LTF13T150, DDPXI41LTF08T150, DDPXI41LTF06T150, MEPXI41LTF20T090, MEPXI41LTF13T090, MEPXI41LTF08T090, MEPXI41LTF06T090, MEPXI41LTF20T150, MEPXI41LTF13T150, MEPXI41LTF08T150, MEPXI41LTF06T150

Scope of Supply
  • Thermal camera Xi 410 LT ETH
  • Ethernet / PoE cable (1 m)
  • USB cable (1m)
  • Cable for output/input (1 m) incl. terminal block
  • Mounting bracket with nut
  • Software package optris PIX Connect
  • Quick Start Guide
Accessories

COMPARE:

Compare