CT 1M

Pyrometer optris CT 1M / 2M for high-temperature measurements of metal

Due to their short measuring wavelength and the high temperature range of up to 2,200°C (3992 °F) the pyrometer optris CT 1M and 2M are ideally suited for employment in high-temperature measurements of metals, metal oxides, and ceramics. The short measuring wavelength of the infrared pyrometer additionally decreases measuring errors during low or changing emission levels.

The small sensor head allows for easy installation in limited and cramped spaces. Moreover, it reliably measures temperatures even in ambient temperatures of up to 125°C (257 °F).

Important specifications

  • Temperature range:
    485°C to 2,200°C (905 °F to 3992 °F) (1M)
    250°C to 2,000°C (482 °F to 3632 °F) (2M)
  • Spectral range: 1.0 µm (1M), 1.6 µm (2M)
  • Response time: 1 ms
  • Starting at $595

From $595.00

Technical Details of the optris CT 1M

Measurement Specifications

  • Temperature range (scalable via software):
    485°C … 1050°C (905 °F … 1929 °F) (1ML)
    650°C … 1800°C (1202 °F … 3272 °F) (1MH)
    800°C … 2200°C (1472 °F … 3992 °F) (1MH1)
    250°C … 800°C (482 °F … 1472) (2ML)
    385°C … 1600°C (725 °F … 2912 °F) (2MH)
    490°C … 2000°C (914 °F … 3632 °F) (2MH1)
  • Spectral range: 1.0 μm (1M) / 1.6 μm (2M)
  • Optical resolution (90% energy):
    CT 1ML / 2ML: 40:1 (2.7 mm @ 110 mm [0.11 in @ 4.33 in])
    CT 1MH / 1MH1 / 2MH / 2MH1: 75:1 (1.5 mm @ 110 mm [0.06 in @ 4.33 in])
  • System accuracy1) (at ambient temperature 23 ± 5°C [73.4 ±41 °F]): ± (0.3% of reading + 2°C [+ 3.6 °F])
  • Repeatability (at ambient temperature 23 ± 5°C [73.4 ±41 °F]): ± (0.1% of reading + 1°C [+ 1.8 °F])
  • Temperature resolution (display): 0.1 K
  • Exposure time2): 1 ms (90%)
  • Emissivity / Gain (adjustable via programming keys or software): 0.100 – 1.100
  • Transmissivity / Gain (adjustable via programming keys or software): 0.100 – 1.100
  • Signal processing (parameter adjustable via programming keys or software, respectively):
    peak hold, valley hold, average, extended hold function with threshold and hysteresis

General Specifications

  • Environmental rating: IP 65 (NEMA-4)
  • Ambient temperature:
    sensing head: -20°C … 100°C (-4 °F … 212 °F) (1M); -20°C … 125°C (-4 °F … 257 °F) (2M)
    electronics: -20°C … 85°C (-4 °F … 185 °F)
  • Storage temperature:
    sensing head: -40°C … 100°C (-40 °F … 212 °F) (1M); -20°C … 125°C (-4 °F … 257 °F) (2M)
    electronics: -40°C … 85°C (-40 °F … 185 °F)
  • Relative humidity: 10 – 95%, non condensing
  • Vibration:IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise)
  • Shock: IEC 60068-2-27 (25G and 50G)
  • Weight:
    sensing head 40 g (1.4 oz)
    electronics 420 g (14.8 oz)

Electrical Specifications

  • Output / analog: 0/4 – 20 mA, 0-5/10 V, thermocouple J, K, alarm
  • Output / alarm: 24 V / 50 mA (open collector)
  • Optional: relay: 2 x 60 V DC/42 V ACeff; 0.4 A; optically isolated
  • Output / digital (optional): USB, RS232, RS485 (optional), Modbus RTU, Profibus DP, Ethernet
  • Output impedances:
    mA max. 500 Ω (with 8-36 V DC)
    mV min. 100 kΩ load impedance
    thermocouple 20 Ω
  • Inputs: programmable functional input for external emissivity setting /ambient temperature compensation, trigger (reset of hold functions)
  • Cable length: 3 m (standard), 8 m, 15 m (9.8 ft [standard], 26.2 ft, 49.2 ft)
  • Power supply: 8-36 V DC
  • Current draw: max. 100 mA

Versions

Part number: temperature range / spectral range / optics / max. ambient temperature / cable length

  • OPTCT1ML: 485 … 1050 °C (905 … 1929 °F) / 1.0 μm / 40:1 / 100°C (212 °F) / 3 m (9.8 ft) cable
  • OPTCT1MH: 650 … 1800 °C (1202 … 3271 °F) / 1.0 μm / 75:1 / 100°C (212 °F) / 3 m (9.8 ft) cable
  • OPTCT1MH1: 800 … 2200 °C (1472 … 3992 °F) / 1.0 μm / 75:1 / 100°C (212 °F) / 3 m (9.8 ft) cable

1) Ɛ = 1, Exposure time 1 s
2) with dynamic adaptation at low signal levels

Areas of application for the pyrometer optris CT 1M

The infrared thermometers optris CT 1M and 2M are employed for temperature measurements requiring short measuring wavelengths. They precisely and reliably measure e.g. metallic surfaces in metal processing (e.g. welding, sintering) as well as metal oxides and ceramics in temperatures of up to 2,200°C (3992 °F).

Infrared software optris Compact Connect included

The temperature analysis software optris Compact Connect has been developed specifically for the extensive documentation and analysis of temperature measurement data of our stationary infrared thermometers. It is license-free and included in every pyrometer shipment.

Accessories