Scope of Supply: Bottom up Glass Inspection System
• Either PI 640i G7 imager with 90° or 60° FOV imager or PI 450i G7 imager with 80° or 53° FOV
• 2x Industrial Process Interface
• CTlaser 4ML glass breakage sensor with USB interface
• 2x DCLP Shutter system with mounting brackets for imagers
• 2x USB Server Gigabit
• Control cabinet with cable set (10 m each) and remote control box
• Software package
• 100-230 V AC/ 24 V DC power supply for initial start-up
Technical Details: optris PI 450i G7 / 640i G7
- Scope of supply:
USB camera incl. 1 lens,
USB cable (1 m),
table tripod,
PIF cable incl. terminal block (1 m),
software package optris PIX Connect,
Rugged outdoor transport case (IP67) - Detector: (FPA, uncooled)
PI 450i G7: 17 µm x 17 µm
PI 640i G7: 17 μm x 17 μm - Optical resolution:
PI 450i G7: 382 x 288 pixels
PI 640i G7: 640 x 480 pixels - Spectral range: 7.9 µm
- Measurement ranges:
150 °C to 900 °C (392 … 2732 °F)
200 °C to 1,500 °C (302 … 1652 °F) - Sighting range: 0 °C to 250 °C (32 … 482 °F)
- Frame rate:
PI 450i G7: 80 Hz/ switchable to 27 Hz
PI 640i G7: 32 Hz / 125 Hz @ 640 x 120 pixels - Optics (FOV) PI 450i G7:
53° x 38° FOV / f = 7,7 mm (f = 0.3 in) or
80° x 54° FOV / f = 5,7 mm (f = 0.22 in) - Optics (FOV) PI 640i G7:
60° x 45° FOV / f = 10.5 mm (f = 0.4 in) or
90° x 64° FOV / f = 7.7 mm (f = 0.3 in) - PI 450i G7: Thermal sensitivity (NETD) at Tobj= 650 °C (1202 °F): 150 mK
PI 640i G7: Thermal sensitivity (NETD) at Tobj= 650 °C (1202 °F): 80 mK - System accuracy (at ambient temperature 23 ± 5°C [73.4 ±41 °F]): ±2 °C (±3.6 °F) or ±2 %
- PC interface: USB 2.0
- Process interface (PIF):
Standard PIF: 0-10 V input, digital input (max. 24V), 0-10 V output
Industrial PIF: 2x 0-10 V inputs, digital input (max. 24 V), 3x 0-10V outputs, 3x relay (0-30 V/ 400 mA), fail-safe relay - Ambient temperature (TAmb):
PI 450i G7: 0 °C…70 °C (32 °F … 158 °F)
PI 640i G7: 0 °C…50 °C (32 °F … 122 °F) - Storage temperature:
PI 450i G7: -40 °C…85 °C (–40 … 185 °F)
PI 640i G7: -40 °C…85 °C (–40 … 185 °F) - Relative humidity: 10 – 95 %, non-condensing
- Enclosure (size / rating):
PI 450i G7: 46 mm x 56 mm x 68 – 77 mm (1.8 x 2.2 x 2.7 – 3.0 in) (depending on lens + focus position) / IP 67 (NEMA 4)
PI 640i G7: 46 mm x 56 mm x 76 – 100 mm [1.8 x 2.2 x 3.0 – 3.9 in] (depending on lens + focus position) / IP 67 (NEMA 4) - Weight:
PI 450i G7: 237 – 251 g [8.36 – 8.85 oz] (depending on lens)
PI 640i G7: 269 – 340 g [10.59 – 13.38 oz] (depending on lens) - Shock / vibration:
PI 450i G7: 25G und 50G, IEC 68-2-27 / IEC 68-2-6 (sinus shaped), IEC 68-2-64 (broadband noise)
PI 640i G7: 25G und 50G, IEC 68-2-27 / IEC 68-2-6 (sinus shaped), IEC 68-2-64 (broadband noise) - Tripod mount: 1/4-20 UNC
- Power supply: USB powered
Technical Details: optris CTlaser 4M
- Temperature range1) (scalable via software):’
0°C … 500°C [32°F to 932°F] (4ML) - Spectral range: 2.2 – 6 μm
- Optical resolution (90% energy):
30:1 (4ML) - System accuracy2) (at Tamb= 23 ± 5°C) [73.4± 41°F]: ± (0.3% of reading + 2°C [1.8°F])
- Repeatability (at Tamb = 23 ± 5°C) [73.4± 41°F]: ± (0.1% of reading + 1°C [0.9 °F])
- NETD: 120 mK
- Exposure time (90% signal)3): 90 μs
- Emissivity / Gain (adjustable via programming keys or software): 0.100 – 1.100
- Transmissivity / Gain (adjustable via programming keys or software): 0.100 – 1.100
- Signal processing (parameter adjustable via programming keys or software, respectively):
peak hold, valley hold, average, extended hold function with threshold and hysteresis - Environmental rating: IP 65 (NEMA-4)
- Ambient temperature:
sensing head: -20°C … 70°C [–4°F … 158°F] (sensing head, 50°C [122°F] with laser ON)
electronics: -20°C … 70°C [–4°F … 158°F] (electronics) - Storage temperature:
sensing head: -40°C … 85°C [–40°F … 185°F] (sensing head)
electronics: -40°C … 85°C [–40°F … 185°F] (electronics) - Relative humidity: 10 – 95%, non condensing
- Vibration: IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise)
- Shock: IEC 60068-2-27 (25G and 50G)
- Weight:
sensing head: 600 g
electronics: 420 g - Outputs / analog: 0/4 – 20 mA, 0-5/10 V, thermocouple K, alarm
- Output / alarm: 24 V / 50 mA (open collector)
- Relay (optional): 2 x 60 V DC/42 V ACeff; 0.4 A; optically isolated
- Outputs/ digital (optional):
built-in USB-interface
Optional: RS232, RS485, Ethernet - Output impedances:
mA max. 500 Ω (with 5 – 36 V DC)
mV min. 100 kΩ load impedance
thermocouple 20 Ω - I/O Pins (3x): flexible programming as in- or output: external emissivity adjustment, ambient temperature
compensation, uncommitted value, trigger (reset of hold functions), alarm output (open collector 24 V/50 mA) - Cable length: 3 m (standard), 8 m, 15 m
- Power supply: 8-36 V DC
- Current draw: max. 160 mA
- Laser 635 nm: 1mW, ON/OFF via electronic box or software