CSlaser 2M

IR thermometer optris CSlaser 2M for measurement of metallic surfaces

The infrared thermometer optris CSlaser 2M has been designed specifically for exact temperature measurement of metallic surfaces. Its short measuring wavelength allows not only for precise measurement of metal temperatures but metal oxides and ceramics as well.

The IR thermometer is equipped with an innovative double laser sight for precise marking of the measuring spot. A variety of scopes ensures high adaptability with various applications.

Important specifications

  • Temperature range:
    250°C to 1,600°C (482 °F to 2912 °F)
  • Spectral range: 1.6 µm
  • Response time: 10 ms
  • Starting at $725

From $795.00

Technical Details of the optris CSlaser 2M

Measurement Specifications

  • Temperature range (scalable via software):
    250°C … 800°C (482 °F … 1472) (2ML)
    385°C … 1600°C (725 °F … 2912 °F) (2MH)
  • Spectral range: 1.6 µm
  • Optical resolution (90% energy):
    150:1 (2ML)
    300:1 (2MH)
  • System accuracy (at Tamb = 23 ± 5°C [73.4 ±41 °F]):
    ± (0,3 % of reading + 2 °C [+ 3.6 °F])
  • Repeatability (at Tamb = 23 ± 5°C [73.4 ±41 °F]):
    ± (0.1 % of reading + 1 °C [+ 1.8 °F])
  • Temperature resolution: 0.1 K
  • Response time (90% signal): 10 ms
  • Emissivity / Gain (adjustable via sensor or software): 0.100 – 1.100
  • IR window correction (adjustable via software): 0.100 – 1.000
  • Signal processing (parameter adjustable via software):
    peak hold, valley hold, average, extended hold function with threshold and hysteresis

General Specifications

  • Environmental rating: IP 65 (NEMA-4) front mountable at vacuum processes (up to 10-3 mbar)
  • Ambient temperature: -20°C … 85°C (-4 °F … 185 °F) (50°C with laser ON)
  • Storage temperature: -40°C … 85°C (-40 °F … 185 °F)
  • Relative humidity: 10 – 95%, non condensing
  • Vibration: IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise)
  • Shock: IEC 60068-2-27 (25G and 50G)
  • Weight: 600 g (21.7 oz)

Electrical Specifications

  • Output / analog: 4-20 mA
  • Loop resistance: max. 1000 Ω1)
  • Output / alarm: 0-30 V/500 mA (open collector)
  • Output/ digital: uni- / bidirectional, 9.6 kBaud, 0/3 V digital level / USB optional
  • Cable length: 3 m [9.8 ft], 8 m [26.2 ft], 15 m [49.2 ft]
  • Power supply: 5-30 V DC
  • Current draw:
    45 mA at 5 V
    20 mA at 12 V
    12 mA at 24 V

Versions

Part number: temperature range / spectral range / optics

  • OPTCSL2ML: 250-800°C (482 … 1472 °F) / 1.6 μm / 150:1
  • OPTCSL2MH: 385-1,600°C (725 … 2912 °F) / 1.6 μm / 300:1

1) in dependence on supply voltage

Accessories